FLC4000 Series


Features

  • Developed as a proprietary controller providing full functions needed for the flow control.
  • Fluorocarbon resin is all used for the wetted part and improved the chemical resistance.
  • Simply constructed so that there are only a pneumatic control valve and ultrasonic flowmeter in the wetted part.
  • Employed air-driven system enabling a high-speed operation compared to the motordriven type.

Measuring range/Pipe size

Control flow range Pipe connection
30 ~ 300mL/min 1/4 PFA tube connection
100 ~ 1000mL/min 3/8 PFA tube connection
200 ~ 2000mL/min
0.1 ~ 1L/min
0.2 ~ 2L/min


Specifications

Measurement subject Liquid
Input signals Analog input 4-20mA/0-5V/1-5V
Single end input
Flow output signal Analog output 4-20mA/0-5V/1-5V
Alarm output operation Instantaneous value One contact alarm output operation at upper/lower limit
Open collector output
Output impressed voltage : Less than 35VDC Sink current : Less than 100mA ( Vol=1.3V )
Fail output When measurement is disabled to take,one contact Fail output operation
Open collector output
Output impressed voltage : Less than 35VDC Sink current : Less than 100mA ( Vol=1.3V )
Power supply DC24V Less than 0.3A MAX2.5A
Wetted mtreials PTFE PFA