Panel Meter
MODEL:419B


Digital Integrating Flow rate Meter

MODEL:419B

● Compact 48 x 48 DIN Size
● Dual Display of flow rate and totalizer
● Pulse output for total and 2 x preset output
● Pulse input 419B

Model Designation

419B 1 1 1 1
1
2
3
4

1. Measuring input
Code Measuring range Input specifications
Blank
Non-voltage output or open collector DC12V 10mA
RE
Voltage pulse "H"=4.5~30V "L"=0~2.0V
Approx.5kΩ
MG
Tachogenerator AC0.8~80Vp-p
SN
Sine wave AC0.1~20Vp-p

2. Power supply voltage
Code Power source voltage
A
AC100V~240V
8
DC12V±10%
9
DC24V±10%

3. Power source for sensor
Code output voltage output current Ripple
Blank
Not available
3
12V±5% 60mA 5% or less
5
24V±5% 30mA 5% or less

4. Analog output, RS-485
Code Output specifications Output impedance Tolerable Load resistive
Blank
-
03
DC0~1V
Approx. 0.1MΩ
200Ω or more
04
DC0~5V 1kΩ or more
05
DC0~10V 2kΩ or more
09
DC1~5V 1kΩ or more
29
DC4~20mA
5MΩ
0~500Ω
E1
RS-485
-

Basic Specifications

Flow rate measurement
Q = fUP where Q is the flow rate,
f is a frequency, U is the user-readable unit of flow(x1, x60, x3600), P is the pulse conversion value
Flow indication 0~9999: Red LED, Character 8mm High, with zero-suppress function.
Decimal point: Programmable form the front key
Over-range indication:Display blank: Changeover to be put on or off.
Display cycle Selectable from the front key. 100ms, 400ms, 1s, 2s, 5s
Moving averaging Selectable from the front key. 1, 2, 3, 4, 8, 16-time
Pulse conversion value Selectable from the front key, from 1x10-6 to 9999
 
Time base Selectable from the front key. Seconds, minutes, or hours
Accuracy ± (0.05%+1digit)
Flow totalize measurement
The meter displays calculation values which is multiplied numbers of input pulse by the K-factor.
Any point can be assigned to initial of total value and be programmed anywhere in the range of the meter.
 
Flow indication 0~99999: Green LED, Character 8mm High, with zero-suppress function.
5 or 10 significant digit: Programmable form the front key
Over-range indication:Display blank: Changeover to be put on or off.
Pulse factor Programmable Pulse factor from the front panel. From 1x10-6 to 999,999 pulses/unit.
P.O output is synchronized to input pulse when exceeding 1.
Primary integrated value from 0 to 99999, programmable from the front key
Display cycle approx. 0.1s
SIG display Light-up when inputting the signal
Common Specifications
 
Input Frequency HF range: 0.01Hz~10kHz
LF range: 0.01Hz~100Hz Programmable from the front key.
Min. Pulse width HF range: 0.05ms / LF range: 5ms
Latch / Pose input Latch: hold display of instantaneous and integrating flow rate, and data output
(except of Simultaneous pulse output). Accumulated integrated count will be operated.
Pose: hold display of instantaneous and integrating flow rate, and data output.
Accumulated integrated count will be temporarily stopped.
Non-voltage contact or open collector (NPN) DC5V 10mA
Active"L", "L"=0~1V, "H"=3.5~5V, 10ms min. Pulse width.
Reset reset to 0 or primary setting value
Backup An EEPROM retains the data of accumulated total flow when the power is interrupted. Keep 10 years.
Output relay contact: AC/DC 150V 80mA
 
Noise filter 1000V against the power line noises
Withstanding Voltage Input terminals - Case : AC1500V each for 1 min.
Power supply terminals - Case : AC1500V each for 1 min.
Power supply terminals - Input and Output terminals : AC1500V each for 1min.
Input terminals - Output terminals : AC500V each for 1 min.
Insulation Resistance DC500V 100MΩor more.
Power Supply AC 100 to 240V (50/60HZ), DC12V±10%, DC24V±10%
Allowable power AC 90 to 250V (50/60Hz), DC10.8 to 13.2V, DC21.6 to 26.4V
Power Consumption Approx. 7.5VA at AC100V, 10VA at AC200V, 400mA at DC12V, 250mA at DC24V.
Operating Temperature 0 to 50℃
Storage Temperature -20 to 70℃
Weight Approx. 160g